Harmony
HARMONic stabilitY assessment of PE-penetrated power systems
|
Insulating layer with optional inner/outer semiconductor radii. More...
#include <Cable.h>
Public Member Functions | |
| Insulator (double ri=0, double ro=0, double permittivity=1, double permeability=1, double innerSemiConductorOuterRadius=0, double outerSemiConductorInnerRadius=0) | |
| Construct a cable insulator layer. | |
Public Attributes | |
| double | ri |
| double | ro |
| double | permittivity |
| double | permeability |
| double | a |
| double | b |
Insulating layer with optional inner/outer semiconductor radii.
|
inline |
Construct a cable insulator layer.
| ri | Inner radius (m). |
| ro | Outer radius (m). |
| permittivity | Relative permittivity epsilon_r. |
| permeability | Relative permeability mu_r. |
| innerSemiConductorOuterRadius | Inner semiconductor outer radius a (m). |
| outerSemiConductorInnerRadius | Outer semiconductor inner radius b (m). |
| double Cable::Insulator::a |
| double Cable::Insulator::b |
| double Cable::Insulator::permeability |
Referenced by Cable::Cable(), and Cable::updateLayers().
| double Cable::Insulator::permittivity |
Referenced by Cable::Cable(), and Cable::updateLayers().
| double Cable::Insulator::ri |
Referenced by Cable::Cable(), and Cable::updateLayers().
| double Cable::Insulator::ro |
Referenced by Cable::Cable(), and Cable::updateLayers().